全国统一客服热线:
0755-28715175

产品中心
Product
4产品中心
Human IL-17 Quantikine ELISA Kit Summary
Human IL-17 Quantikine ELISA Kit Summary
Human IL-17 Quantikine ELISA Kit Summary

Human IL-17 Quantikine ELISA Kit Summary

 详情说明

Human IL-17 Quantikine ELISA Kit Summary

深圳9游总区生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!

货号:D1700

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (100 uL), Serum (100 uL), EDTA Plasma (100 uL), Heparin Plasma (100 uL), Citrate Plasma (100 uL)
Sensitivity
15 pg/mL
Assay Range
31.2 - 2,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma)
Specificity
Natural and recombinant human IL-17
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human IL-17 Immunoassay is a 4.5 hour solid phase ELISA designed to measure human IL-17 in cell culture supernates, serum, and plasma. It contains E. coli-expressed recombinant human IL-17 and antibodies raised against the recombinant factor. This immunoassay has been shown to quantitate recombinant human IL-17 accurately. Results obtained using natural human IL-17 showed linear curves that were parallel to the standard curves obtained using the recombinant Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for natural human IL-17.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 131 736 1480 125 408 794
Standard Deviation 5.8 34.6 61.2 9.8 34.3 55.6
CV% 4.4 4.7 4.1 7.8 8.4 7

Cell Culture Supernates

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 107 604 1217 76.6 272 549
Standard Deviation 7.8 25 63.3 6.5 23.4 43.9
CV% 7.3 4.1 5.2 8.5 8.6 8

Recovery

The recovery of human IL-17 spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=5) 97 88-112
Citrate Plasma (n=5) 105 92-116
EDTA Plasma (n=5) 101 90-110
Heparin Plasma (n=5) 101 93-109
Serum (n=5) 98 90-105

Linearity

To assess the linearity of the assay, five samples spiked with high concentrations of IL-17 were diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Human IL-17/IL-17A ELISA Linearity