Human CCL5/RANTES Quantikine ELISA Kit
Human CCL5/RANTES Quantikine ELISA Kit
Human CCL5/RANTES Quantikine ELISA Kit Summary
深圳9游总区生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!
货号:DRN00B
Sample Type & Volume Required Per Well
Cell Culture Supernates (100 uL), Serum (100 uL), EDTA Plasma (100 uL), Heparin Plasma (100 uL), Citrate Plasma (100 uL), Urine (100 uL)
Assay Range
31.2 - 2,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine)
Specificity
Natural and recombinant human RANTES
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.
Product Summary
The Quantikine Human RANTES Immunoassay is a 3.5 hour solid phase ELISA designed to measure human RANTES levels in cell culture supernates, serum, plasma, and urine. It contains E. coli-derived recombinant human RANTES and antibodies raised against the recombinant factor. This immunoassay has been shown to accurately quantitate the recombinant factor. Results obtained using natural human RANTES showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values of natural human RANTES.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
Cell Culture Supernates, Serum, Urine
|
Intra-Assay Precision
|
Inter-Assay Precision
|
Sample
|
1
|
2
|
3
|
1
|
2
|
3
|
n
|
20
|
20
|
20
|
20
|
20
|
20
|
Mean
|
91.9
|
573
|
1120
|
92
|
511
|
1105
|
Standard Deviation
|
2.3
|
10
|
32.4
|
6.2
|
32.7
|
70.7
|
CV%
|
2.5
|
1.7
|
2.9
|
6.7
|
6.4
|
6.4
|
EDTA Plasma, Heparin Plasma, Citrate Plasma
|
Intra-Assay Precision
|
Inter-Assay Precision
|
Sample
|
1
|
2
|
3
|
1
|
2
|
3
|
n
|
20
|
20
|
20
|
20
|
20
|
20
|
Mean
|
108
|
599
|
1191
|
88
|
494
|
1063
|
Standard Deviation
|
3.9
|
14.3
|
41.5
|
9.1
|
43.1
|
89.6
|
CV%
|
3.6
|
2.4
|
3.5
|
10.3
|
8.7
|
8.4
|
Recovery
The recovery of RANTES spiked to levels throughout the range of the assay in various matrices was evaluated.
Sample Type
|
Average % Recovery
|
Range %
|
Cell Culture Media (n=4)
|
101
|
95-110
|
Platelet-poor Citrate Plasma (n=4)
|
99
|
93-105
|
Platelet-poor EDTA Plasma (n=4)
|
98
|
93-103
|
Platelet-poor Heparin Plasma (n=4)
|
99
|
93-105
|
Serum (n=5)
|
101
|
94-107
|
Urine (n=10)
|
102
|
88-114
|
Linearity