Human GDF-15 Quantikine ELISA Kit
Human GDF-15 Quantikine ELISA Kit
Human GDF-15 Quantikine ELISA Kit Summary
深圳9游总区生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!
货号:DGD150
Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), Serum (13 uL), EDTA Plasma (13 uL), Heparin Plasma (13 uL), Urine (10 uL)
Assay Range
23.4 - 1,500 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine)
Specificity
Natural and recombinant human GDF-15
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.Cross-species reactivity not tested.
Interference
No significant interference observed with available related molecules.
Product Summary
The Quantikine Human GDF-15 immunoassay is a 3.5 hour solid phase ELISA designed to measure GDF-15 in cell culture supernates, serum, plasma, and urine. It contains CHO cell-expressed recombinant human GDF-15 and has been shown to accurately quantitate the recombinant factor. Results obtained using natural GDF-15 showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values of naturally occurring GDF-15.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine
|
Intra-Assay Precision
|
Inter-Assay Precision
|
Sample
|
1
|
2
|
3
|
1
|
2
|
3
|
n
|
20
|
20
|
20
|
40
|
40
|
40
|
Mean
|
238
|
456
|
886
|
225
|
442
|
900
|
Standard Deviation
|
4.27
|
9.86
|
25
|
13.4
|
20.6
|
50.5
|
CV%
|
1.8
|
2.2
|
2.8
|
6
|
4.7
|
5.6
|
Recovery
The recovery of GDF-15 spiked to levels throughout the range of the assay in various matrices was evaluated.
Sample Type
|
Average % Recovery
|
Range %
|
Cell Culture Media (n=4)
|
100
|
94-106
|
EDTA Plasma (n=4)
|
97
|
85-108
|
Heparin Plasma (n=4)
|
96
|
86-108
|
Serum (n=4)
|
98
|
88-107
|
Urine (n=4)
|
102
|
88-108
|
Linearity
To assess the linearity of the assay, samples containing and/or spiked with high concentrations of GDF-15 were serially diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay.