Human IL-7 Quantikine HS ELISA Kit
Human IL-7 Quantikine HS ELISA Kit
Human IL-7 Quantikine HS ELISA Kit

Human IL-7 Quantikine HS ELISA Kit

 详情说明

Human IL-7 Quantikine HS ELISA Kit Summary

深圳9游总区生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!

货号:HS750

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
18-24 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (200 uL), Serum (200 uL), EDTA Plasma (200 uL), Citrate Plasma (200 uL)
Sensitivity
0.1 pg/mL
Assay Range
0.2 - 10 pg/mL (Cell Culture Supernates), 0.3 - 16 pg/mL (Serum, EDTA Plasma, Citrate Plasma)
Specificity
Natural and recombinant human IL-7
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine HS Human IL-7 Immunoassay is a solid phase ELISA that specifically measures IL-7 in 18-24 hours (with an overnight incubation step). This kit is designed to measure IL-7 levels in cell culture supernates, serum, and plasma. It contains E. coli-expressed recombinant human IL-7 and antibodies raised against the recombinant factor. It has been shown to quantitate the recombinant factor accurately. Results obtained using natural IL-7 showed linear curves that were parallel to the standard curves obtained using the kit standards. These results indicate that this kit can be used to determine relative mass values for natural human IL-7.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Serum, EDTA Plasma, Citrate Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 0.46 5.79 11.18 0.51 6.38 12.95
Standard Deviation 0.03 0.19 0.44 0.06 0.5 1.3
CV% 6.5 3.3 3.9 11.8 7.8 10

Cell Culture Supernates

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 0.5 1.49 6.86 0.78 2.13 8.81
Standard Deviation 0.04 0.14 0.61 0.08 0.16 0.64
CV% 8 9.4 8.9 10.3 7.5 7.3

Recovery

The recovery of IL-7 spiked to three different levels throughout the range of the assay was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=5) 103 89-113
Citrate Plasma (n=5) 100 92-110
EDTA Plasma (n=5) 112 83-132
Serum (n=5) 100 91-113

Linearity

To assess the linearity of the assay, samples were spiked with high concentrations of IL-7 and diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.