Human G-CSF Quantikine ELISA Kit Summary
Human G-CSF Quantikine ELISA Kit Summary
Human G-CSF Quantikine ELISA Kit Summary

Human G-CSF Quantikine ELISA Kit Summary

 详情说明

Human G-CSF Quantikine ELISA Kit Summary

深圳9游总区生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!

货号:DCS50

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
3.5 hours or 4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (100 uL), Serum (100 uL), EDTA Plasma (100 uL), Heparin Plasma (100 uL), Citrate Plasma (100 uL)
Sensitivity
20 pg/mL
Assay Range
39.0 - 2,500 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma)
Specificity
Natural and recombinant human G-CSF
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human G-CSF Immunoassay is a 3.5 or 4.5 hour solid phase ELISA designed to measure G-CSF in cell culture supernates, serum, and plasma. It contains E. coli-expressed recombinant human G-CSF and antibodies raised against the protein. It has been shown to accurately quantitate recombinant human G-CSF. Results obtained using natural human G-CSF showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for natural human G-CSF.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Cell Culture Supernates

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 177 515 1047 143 818 1514
Standard Deviation 4.5 9.4 22 17 72 77.1
CV% 2.5 1.8 2.1 11.9 8.8 5.1

Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 280 827 1696 176 1094 2169
Standard Deviation 7.8 14.1 19.5 7.3 34.6 81.6
CV% 2.8 1.7 1.1 4.1 3.2 3.8

Recovery

The recovery of G-CSF spiked to three different levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=5) 94 85-110
Citrate Plasma (n=5) 90 78-111
EDTA Plasma (n=5) 93 80-117
Heparin Plasma (n=5) 87 76-103
Serum (n=5) 88 75-106

Linearity

To assess the linearity of the assay, five samples were spiked with high concentrations of G-CSF in various matrices and diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Human G-CSF ELISA Linearity