Human ADAMTS13 Quantikine ELISA Kit
Human ADAMTS13 Quantikine ELISA Kit
深圳9游总区生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!
Human ADAMTS13 Quantikine ELISA Kit Summary
货号:DADT130 规格:96T
Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), Serum (10 uL), EDTA Plasma (10 uL), Heparin Plasma (10 uL), Citrate Plasma (10 uL)
Assay Range
0.8 - 50 ng/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma)
Specificity
Natural and recombinant human ADAMTS13. This kit also recognizes a truncated version of recombinant human ADAMTS13 (amino acids Gln34-Trp688; Accession # NP_620594).
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.Cross-species reactivity not tested.
Interference
No significant interference observed with available related molecules.
Product Summary
The Quantikine Human ADAMTS13 Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human ADAMTS13 in cell culture supernates, serum, and plasma. It contains CHO cell-expressed recombinant human ADAMTS13 and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human ADAMTS13 showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring human ADAMTS13.
Precision
Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Citrate Plasma
|
Intra-Assay Precision
|
Inter-Assay Precision
|
Sample
|
1
|
2
|
3
|
1
|
2
|
3
|
n
|
20
|
20
|
20
|
20
|
20
|
20
|
Mean
|
4.78
|
13.8
|
29.7
|
4.51
|
14.2
|
30.2
|
Standard Deviation
|
0.177
|
0.364
|
0.685
|
0.256
|
0.722
|
1.08
|
CV%
|
3.7
|
2.6
|
2.3
|
5.7
|
5.1
|
3.6
|
Recovery
The recovery of ADAMTS13 spiked to levels throughout the range of the assay in various matrices was evaluated.
Sample Type
|
Average % Recovery
|
Range %
|
Cell Culture Media (n=8)
|
100
|
91-111
|
Citrate Plasma (n=4)
|
97
|
87-114
|
EDTA Plasma (n=4)
|
97
|
89-109
|
Heparin Plasma (n=4)
|
97
|
85-115
|
Serum (n=4)
|
97
|
85-106
|
Linearity